94 Quantum MP User Guide
www.emersonct.com Issue: A3
ARMATURE_VOLTAGE_MAX
[1025]
Maximum armature voltage
Vac x 1.35 (2 x 3 / π)
480 +10% drive: 720
575 +10% drive: 860
690 +10% drive: 1025
For 4 quadrant drives maximum armature voltage = Vac x 1.15
QUADRANT_MAX
Quadrant maximum
0 for a 2 quadrant drive.
1 for a 4 quadrant drive.
POWER_MAX
[9999.99kW]
Maximum power in kW
The maximum power has been chosen to allow for the maximum power that can be output by the drive with
maximum DC output voltage and maximum controlled current.
Therefore:
POWER_MAX = ARMATURE_VOLTAGE_MAX x DRIVE_CURRENT_MAX
The values given in square brackets indicate the absolute maximum value allowed for the variable maximum.
Maximum Definition