3M Multimedia Projector MP8620 Disassembly/Reassembly
3M 1999 2-4
1
2
3
4
5
2-3-3. Remove Lamp Assembly
To avoid electrical shocks, unplug projector
power cord before performing any maintenance
to electrical components.
To avoid burns to fingers, allow projector lamp
and internal projector components to cool off prior
to lamp removal or disassembly.
1. Remove two (2) screws from bottom of base.
2.
Depress lock tab and slide cover to remove.
3.
Lift latch to release lamp panel and lower panel to the
open position.
Note
Do not touch lamp glass with fingers. Oil from
fingers can reduce lamp life.
4. Release wire from wire holder.
5.
Return lamp panel to the closed position.
6.
Remove EMI shield. (See Section 2-3-2.)
!
!
WARNING
Vista de pagina 19