Page 34 Model 801GC-ISA & 801GF-ISA Programming Manual
VSPW <lines>
Limits: <lines> =
Description: The VSPW command establish the width of the vertical sync pulse in lines. If the type
specified for the selected sync signal (see SSST, ASCT, DSCT, or DSST commands) is one of
the CCIR types, then the actual sync pulse width output by the generator will be 1/2 line
shorter than the whole number specified. The VSPW? query returns the current setting of
VSPW.
VTOT <lines>
Limits: <lines>
min = 2
max = 65535
Must be an odd number when SCAN = 2
Description: The VTOT command establishes the total number of lines per frame. When interlacing
(SCAN=2), VTOT must be odd. The VTOT? query returns the current setting of VTOT.
The frame or picture refresh rate is equal to the quotient of: HRAT divided by VTOT.
The field or vertical rate is equal to the frame rate when SCAN = 1 (non-interlaced
operation).
The field or vertical rate is equal to twice the frame rate when SCAN = 2 (non-interlaced
operation).
The current version of the firmware does not allow you to directly enter a specific field
or frame rate when setting up a format. If your test specifications call for a specific field,
frame or vertical refresh rate, enter suitable values for HRAT, SCAN and VTOT to give
you the desired rate.
XVSG <red mode>, <green mode>, <blue mode>
Limits: <all modes>
0 = OFF
1 = ON
Description: The XVSG command determines which video outputs will be active when the format is
selected. The same command controls both the analog and digital video outputs.