370 Appendix A Command Reference
HSPD
Horizontal Sync Pulse Delay
Class Format parameter setting - Synchronization
Description Establishes the delay between the leading edge of blanking and the leading edge of the
horizontal sync pulse. The HSPD? query returns the current setting of HSPD.
Command syntax HSPD pixels
pixels
min = 1
max = HTOT - HRES - HSPW
Query syntax HSPD?
Query response pixels
Other required
commands
The FMTU command instructs the generator to use the new settings. The ALLU command
updates the hardware to the new settings and redraws the test image.
Example
HSPD 16 // Set 16 pixel pulse delay in buffer
FMTU // Update hardware to current buffer contents