Quantum Data 802R Guía de usuario Pagina 548

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 744
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 547
538 Appendix A Command Reference
STRG
STRetchinG SCL Low Signal
Class EDID and DDC control
Description Enables a stretching capability for the receiver of the HDMI analyzer. Each time a host
accesses the I2C receiver bus (for example, to read the EDID), the receiver stretches the
SCL low signal for 5 ms.
Enable stretching for testing purposes only.
Command syntax STRG value
value
0 = deactivate stretching
1 = activate stretching of SCL low signal for 5 ms
Query syntax STRG?
Query response 0 or 1
Example
STRG 1
DIDU
Related commands DIDU
Vista de pagina 547
1 2 ... 543 544 545 546 547 548 549 550 551 552 553 ... 743 744

Comentarios a estos manuales

Sin comentarios